Page 1. Page 2. Page 3. Page 4. Page 5. Page 6. Page 7. Page 8. Page 9. Page Page Page Page Page Page Page Page Page View and Download Potterton Prima 30F installation and servicing instructions online. Fanned balanced flue gas fired boilers. Prima 30F Boiler pdf manual. Potterton Prima F Pdf User Manuals. View online or download Potterton Prima F Installation And Servicing Instructions.

Author: Sharan Goltikazahn
Country: United Arab Emirates
Language: English (Spanish)
Genre: Technology
Published (Last): 22 February 2013
Pages: 136
PDF File Size: 11.12 Mb
ePub File Size: 2.17 Mb
ISBN: 641-4-74864-656-5
Downloads: 58499
Price: Free* [*Free Regsitration Required]
Uploader: Arashirn

Ensure that it is level and the correct way upi. By pressing ‘print’ button you will print only current page. It shall be potterton prima f manual in the flow pipe either horizontally or vertically upwards and close v the boiler.

Remove the pilot injector and maunal its orifice or replace. If a three potterton prima f manual diverter valve is used as shown in FIGS. Clean or replace the injector.

Repair is by replacement. When the pressure and rate are correct replace the plastic cap on the SIT gas control valve. This manual also for: Any direct connection of a control device not approved by Potterton Myson could invalidate the certification and the potterton prima f manual warranty. Remove the screw securing the pressure switch to the bracket in the control box.

Potterton Prima 60F Manuals

Small quantities of adhesives and sealants used in the product are cured and present no known hazards. Two methods of filling a sealed water system. Potterton prima f manual supply to the boiler and its associated equipment should be controlled by an exclusive 3A fused double pole switch having potterton prima f manual least 3mm contact separation in both poles so that complete isolation from the supply can be achieved to enable servicing work to be carried out in safety.

Turn off the external electricity supply and gas service cock. Vertex Flue Kitgiving greater vertical flueing flexibility through a roof space Prima 30F to 60F only. Re-instate the external electricity supply. The thermostat has been calibrated by the makers and no attempt should be made to re-calibrate it on site.

Potterton Prima 30F

Insert an approved ammeter in series with the spark electrode. If necessary make good around hole to enable holes ‘ B ‘ to be drilled.

Sealed phial and capillary containing liquid. Ensure the rubber grommet in the base of the boiler makes a good seal around the capillary.

Replacement is the reverse of removal. Connect system pipework to the boilercompression fittings should be used.

Turn the boiler thermostat to ‘ O ‘. Control Thermostat K36 L Check the combustion chamber insulation for damage.

Ensure that the gasket between fan outlet and elbow or adapter is undamaged and in place. Secure the pilot assembly to the main burner using two hexagonal screws. Undo securing screwpull controls cover forward 10mmlower it to release it from its four side fixings nanual pull forward clear of the thermostat knob. Alsosystems fitted with controls that close both hot water and central. Gas will flow to the pilot only. Potterton prima f manual template and carefully cut flue outlet hole through wall.

Small quantities of adhesives and sealants used in potterton prima f manual product are cured and present no known hazards. Performance data is based on use of reference gas G Unplug the gas control valve supply lead from the control janual and plug it into the test socket potterton prima f manual to the boiler thermostat knobSee FIG.

Remove gas control valve plug from the test socket and refit the plug into the socket on the left hand side of the control box.